Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Journal of Regional Anatomy and Operative Surgery ; (6): 34-37, 2019.
Article in Chinese | WPRIM | ID: wpr-744544

ABSTRACT

Objective To evaluate the clinical effect of electromagnetic navigation system to locate the distal locking screw of tibia intramedullary nail. Methods From February 2010 to December 2016, 79 cases of tibia shaft fractures requiring treatment with intramedullary nailing were selected and divided into the navigation group and free hand locking group according to intramedullary nail locking methods. Forty-four cases in navigation group used an electromagnetic navigation system to lock the distal end of the intramedullary nail,while 35 cases in free hand locking group used a free-hand technique. The intraoperative X-ray exposure time,distal locking time,healing time, and the success rate of one-time distal locking were recorded compared between two groups. Results The average time of diatal locking using electromagnetic navigation technology was less than that of the free hand locking group,and the exposure time of fluoroscopy was also reduced, the differences were significant(P < 0. 05). There was no difference in fracture healing time between the two groups(P > 0. 05), one-time success rate of navigation group was 100%,which was higher than 37. 34% of the free hand locking group, the difference was significant(P < 0. 05). Conclusion Compared with free hand technology, the advantage of using electromagnetic navigation system to lock the distal nail of tibia intramedullary nail is high efficiency, short locking time and no radiation.

2.
Journal of Korean Neurosurgical Society ; : 75-80, 2018.
Article in English | WPRIM | ID: wpr-788652

ABSTRACT

OBJECTIVE: Among the various sacropelvic fixation methods, S2 alar-iliac (S2AI) screw fixation has several advantages compared to conventional iliac wing screw. However, the placement of S2AI screw still remains a challenge. The purpose of this study was to describe a novel technique of free hand S2AI screw insertion using a K-wire and cannulated screw, and to evaluate the accuracy of the technique.METHODS: S2AI screw was inserted by free hand technique in sixteen consecutive patients without any fluoroscopic guidance. The gearshift was advanced to make a pilot hole passing through the sacroiliac joint and directing the anterior inferior iliac spine. A K-wire was placed through the pilot hole. After introducing a cannulated tapper along with the K-wire, a cannulated S2AI screw was installed over the K-wire.RESULTS: Thirty-three S2AI screws were placed in sixteen consecutive patients. Thirty-two screws were cannulated screws, and one screw was a conventional non-cannulated screw. Thirty out of 32 (93.8%) cannulated screws were accurately positioned, whereas two cannulated screws and one non-cannulated screw violated lateral cortex of the ilium.CONCLUSION: The technique using K-wire and cannulated screw can provide accurate placement of free hand S2AI screw.


Subject(s)
Humans , Hand , Ilium , Sacroiliac Joint , Spine
3.
Journal of Korean Neurosurgical Society ; : 75-80, 2018.
Article in English | WPRIM | ID: wpr-765222

ABSTRACT

OBJECTIVE: Among the various sacropelvic fixation methods, S2 alar-iliac (S2AI) screw fixation has several advantages compared to conventional iliac wing screw. However, the placement of S2AI screw still remains a challenge. The purpose of this study was to describe a novel technique of free hand S2AI screw insertion using a K-wire and cannulated screw, and to evaluate the accuracy of the technique. METHODS: S2AI screw was inserted by free hand technique in sixteen consecutive patients without any fluoroscopic guidance. The gearshift was advanced to make a pilot hole passing through the sacroiliac joint and directing the anterior inferior iliac spine. A K-wire was placed through the pilot hole. After introducing a cannulated tapper along with the K-wire, a cannulated S2AI screw was installed over the K-wire. RESULTS: Thirty-three S2AI screws were placed in sixteen consecutive patients. Thirty-two screws were cannulated screws, and one screw was a conventional non-cannulated screw. Thirty out of 32 (93.8%) cannulated screws were accurately positioned, whereas two cannulated screws and one non-cannulated screw violated lateral cortex of the ilium. CONCLUSION: The technique using K-wire and cannulated screw can provide accurate placement of free hand S2AI screw.


Subject(s)
Humans , Hand , Ilium , Sacroiliac Joint , Spine
4.
Korean Journal of Spine ; : 7-13, 2013.
Article in English | WPRIM | ID: wpr-199863

ABSTRACT

OBJECTIVE: A variety of different pedicle screws entry point techniques are used for the lumbar pedicle screws placement. This study reported Kim's entry point of lumbar pedicle screws with free hand technique and the accuracy of this technique. METHODS: We retrospectively reviewed the 584 cases with free hand placed lumbar pedicle screw placement. The diagnosis included 491 cases with degenerative spine, 59 cases with trauma, 29 cases with metastatic disease, and 5 cases with scoliosis. A total of 2601 lumbar pedicle screws were placed, and the entry points of lumbar pedicle screws were the junction of proximal edge of transverse process and lamina. Incidence and extent of cortical breach by misplaced pedicle screw was determined by review of intra-operative and post-operative radiographs and/or computed tomography. RESULTS: Among the total 2601 lumbar free hand placed pedicle screws, 114 screws (4.4%) in 79 patients (13.5%) were repositioned screws with suspected screw malposition during operation, and 37 screws (1.4%) in 31 patients (5.3%) were identified as moderate to severe breaching the pedicle after post-operative imaging studies. Among the patient with malpositioned screws, 3 patients showed nerve irritation sign of the lesion, and 2 cases were symptom improved after nerve block and conservative management, and 1 case was removed the screw after the failure of the treatment. CONCLUSION: Free hand pedicle screw placement based on external landmark with the junction of proximal edge of transverse process and lamina showed acceptable safety and accuracy and avoidance of radiation exposure.


Subject(s)
Humans , Hand , Incidence , Nerve Block , Retrospective Studies , Scoliosis , Spine
5.
Journal of Korean Neurosurgical Society ; : 66-70, 2012.
Article in English | WPRIM | ID: wpr-145557

ABSTRACT

Thoracic pedicle screw fixation techniques are still controversial for thoracic deformities because of possible complications including neurologic deficit. Methods to aid the surgeon in appropriate screw placement have included the use of intraoperative fluoroscopy and/or radiography as well as image-guided techniques. We describe our technique for free hand pedicle screw placement in the thoracic spine without any radiographic guidance and present the results of pedicle screw placement analyzed by computed tomographic scan in two human cadavers. This free hand technique of thoracic pedicle screw placement performed in a step-wise, consistent, and compulsive manner is an accurate, reliable, and safe method of insertion to treat a variety of spinal disorders, including spinal deformity.


Subject(s)
Humans , Cadaver , Congenital Abnormalities , Fluoroscopy , Hand , Neurologic Manifestations , Spine
6.
Journal of Korean Neurosurgical Society ; : 300-302, 2005.
Article in English | WPRIM | ID: wpr-98546

ABSTRACT

The authors report a case of hyperacute, massive hemorrhage in the left basal ganglia with severe midline shift that was treated successfully by the ultrasound-monitored free hand aspiration technique. Every effort was made to shorten time until removal of considerable amount of the hematoma and minimize duration of cerebral herniation, avoiding additional irreVersible neurological deficit. A burr hole aspiration technique was preferred to standard craniotomy procedure, and any time-consuming procedures such as stereotactic frame application were abandoned. A burr hole was localized on the basis of computed tomography images simply and quickly with a ruler, and safety of the aspiration procedure was augmented by real-time ultrasound monitoring. Such minimally invasive technique relieved cerebral herniation successfully while avoiding time consumption and the morbidity of major craniotomy procedure. Early resuscitation of the patient with cerebral herniation in this case resulted in excellent recovery of the patient's neurological deficit. The patient's mentality started to improve rapidly and was clear six months after the surgery.


Subject(s)
Humans , Basal Ganglia , Cerebral Hemorrhage , Craniotomy , Hand , Hematoma , Hemorrhage , Resuscitation , Ultrasonography
SELECTION OF CITATIONS
SEARCH DETAIL